![]() | ELDRO® Electrohydraulic Thrusters Technical Data |
Ed 23/5, Ed 30/5, Ed 50/6, Ed 80/6, Ed 50/12, Ed 80/12![]() | |||
| Performance In Service Depending On Ambient Temperatures | |||
| Temperature Range | Hydraulic Fluid | Performance In Service | |
| -25°C to + 50°C | HL 10, DIN 51524, part 1 | In the lower range of ambient temperatures the lifting times may increase up to four times the specified lifting times when the unit is operated the first time. The lowering times remain unaffected. | |
| over +50°C | Special fluid | Inquire | |
| below -25°C* | Special, low temperature fluid. | Space heater not required. | |
| below -25°C* | HL 10, DIN 51524, part 1 | Space heater required in unit. Connect up heater in terminal box using an additional Pg 16 cable gland. 220 or 110 volt connected voltage. Thermostatic control to be provided by customer. | |
| Type | Lifting Force N | Stroke mm | Thrust N cm | Brake Spring Force (c - spring)* N | Power Consumption** W | Current Consumption at 380 V** A | Duty Rating at S3 - 60% Duty Cycle*** c/h | Weight kg |
| Short Stroke Units | ||||||||
| Ed 23/5 | 220 | 50 | 1100 | 180 | 165 | 0.5 | 2000 | 10 |
| Ed 30/5 | 300 | 50 | 1500 | 270 | 200 | 0.5 | 2000 | 14 |
| Ed 50/6 | 500 | 60 | 3000 | 460 | 210 | 0.5 | 2000 | 23 |
| Ed 80/6 | 800 | 60 | 4800 | 750 | 330 | 1.2 | 2000 | 24 |
| Ed 121/6 | 1250 | 60 | 7500 | 1200 | 330 | 1.2 | 2000 | 39 |
| Ed 201/6 | 2000 | 60 | 12000 | 1900 | 450 | 1.3 | 2000 | 39 |
| Ed 301/6 | 3000 | 60 | 18000 | 2700 | 550 | 1.4 | 1500 | 40 |
| Long Stroke Units | ||||||||
| Ed 50/12 | 500 | 120 | 6000 | - | 210 | 0.5 | 1200 | 26 |
| Ed 80/12 | 800 | 120 | 9600 | - | 330 | 1.2 | 1200 | 27 |
| Ed 121/12 | 1250 | 120 | 15000 | - | 330 | 1.2 | 1200 | 39 |
| Ed 201/12 | 2000 | 120 | 24000 | - | 450 | 1.3 | 1200 | 39 |
| Ed 301/12 | 3000 | 120 | 36000 | - | 550 | 1.4 | 900 | 40 |
| All technical data are mean values related on +20°C operating temperature of unit. *   Values of braking force apply to 1/3 of the rated stroke. ** Values at the end position of piston. During lifting operation the specified values multiply.     At -25°C operating temperature of unit the current consumption is apprx. 1.5 times the current consumption at +20°C. ***Continuous operation S1 and intermittent service S3 permitted up to +50°C ambient temperature. | ||||||||
| Performance In Service Depending On Ambient Temperatures | Ed 121/6, Ed 201/6, Ed 301/6, Ed 121/12, Ed 201/12, Ed 301/12 ![]() | ||
| Temperature Range | Hydraulic Fluid | Performance In Service | |
| -25°C to + 50°C | HL 10, DIN 51524, part 1 | In the lower range of ambient temperatures the lifting times may increase up to four times the specified lifting times when the unit is operated the first time. The lowering times remain unaffected. | |
| over +50°C | Special fluid | Inquire | |
| below -25°C* | Special, low temperature fluid. | Space heater not required. | |
| below -25°C* | HL 10, DIN 51524, part 1 | Space heater required in unit. Connect up heater in terminal box using an additional Pg 16 cable gland. 220 or 110 volt connected voltage. Thermostatic control to be provided by customer. | |